Connection configuration
This section lists the properties you can set for ODBC or JDBC connections.
Setting properties for ODBC
Not all the parameters Simba accepts are supported by the ThoughtSpot ODBC clients, and ThoughtSpot has added some properties, which are listed separately here. All configuration properties use the type String (text).
You can set these properties on Windows by using the ODBC administrator client. For Linux, the properties are located in three files, depending on the property type:
- DSN
-
- Location
-
odbc.ini
file
- Driver
-
- Location
-
odbsinst.ini
file
- SimbaSetting Reader
-
- Location
-
simbaclient.ini
file
Setting properties for JDBC
For JDBC, these properties are passed as key value pairs in the connect string. For more information, see Use the JDBC Driver.
Properties reference
The following tables summarize the configuration properties.
- DATABASE
-
The default database for connecting.
- Type
-
DSN or Driver
- SCHEMA
-
The default schema to connect to.
- Type
-
DSN or Driver
- Description
-
A brief, human-readable description of the DSN. This describes the DSN to users who are deciding which DSN to use.
- Type
-
DSN
- Driver
-
In the driver configuration location, Driver should contain the path to the driver binary. In the DSN configuration location, Driver could contain the path to the driver binary, or it could contain the driver entry in the registry.
- Type
-
DSN or Driver
- IdleTimeout
-
The time to wait for a response from the server, in seconds. This property is optional, but SimbaClient will wait indefinitely for SimbaServer to respond to a request made to the server unless you specify a timeout period.
IdleTimeout
specifies how many seconds that SimbaClient will wait before aborting the attempt and returning to the application with an error. This timeout corresponds to ODBC’sCONNECTION_TIMEOUT
property and is only used when more specific timeouts, such asQUERY_TIMEOUT
orLOGIN_TIMEOUT
aren’t applicable.- Type
-
DSN
- Locale
-
The connection locale. If this value is set, it overrides the driver-wide locale. For example, the driver-wide locale could be
en-US
. If the client would preferfr-CA
, it can set the connection locale tofr-CA
.
Values are composed of a 2-letter language code (in lower case), and an optional 2-letter country code (in upper case). If the country code is specified, it must be separated from the language code by a hyphen (-).- Type
-
DSN
- LoginTimeout
-
The timeout, in seconds, to wait for a response from the server when attempting to log in. A value of 0 means no timeout. The default value is 60.
- Type
-
DSN
- QueryTimeout
-
The timeout, in seconds, to wait for a response from the server during Prepare, Execute, and ExecuteDirect. A value of 0 means no timeout. The default value is 60.
- Type
-
DSN
- ServerList
-
A comma separated list of all servers (IP address and port number) to connect to. SimbaClient must be able to find SimbaServer on the network. This property enables server discovery. SimbaClient will try to make a network connection to the servers in the order specified until a connection is made.
- Type
-
DSN
- LogLevel
-
Controls the granularity of the messages and events that are logged.
With this keyword, you can control the amount of log output by controlling the kinds of events that are logged.
- Type
-
SimbaSetting Reader
- Possible values
-
(case sensitive)
0
orLOG_OFF
no logging
1
orLOG_FATAL
only log fatal errors
2
orLOG_ERROR
log all errors
3
orLOG_WARNING
log all errors and warnings
4
orLOG_INFO
log all errors, warnings, and informational messages
5
orLOG_DEBUG
log method entry, exit points, and parameter values for debugging
6
orLOG_TRACE
log all method entry points
- LogPath
-
Specifies the directory where to create the log files. For example:
LogPath=C:\Simba Technologies\Temp
If this value is not set, the log files are written to the current working directory of the SimbaClient.
- Type
-
SimbaSetting Reader
- LogFileSize
-
The size of each log file, in bytes. When the maximum size of the file is reached, the system creates a new file.
- Type
-
SimbaSetting Reader
- Default value
-
20971520 bytes
- LogFileCount
-
The number of log files to create. When the maximum number of log files has been created, the oldest file will be deleted and a new one created.
- Type
-
SimbaSetting Reader
- Default value
-
50
- username
-
Part of a user username/password combination. This combination should correspond to a ThoughtSpot application user with permissions appropriate to your ETL requirements.
Typically, this user is a user with data management or administrative privileges on the application.
- Type
-
UID
- password
-
Part of a user username/password combination. This combination should correspond to a ThoughtSpot application user with permissions appropriate to your ETL requirements.
Typically, this user has data management or administrative privileges on the application.
- Type
-
Password